Redundancy

Overview

Redundancy is having more than one: more than one instance, more than one node, more than one network path, more than one provider.

The arithmetic is attractive. Two components at 99% availability each, if independent, give 99.99% combined.

The word that decides everything is the emphasized one. Correlated failures — the ones that hit every copy at the same time — nullify redundancy, and they are far more common than the arithmetic suggests.

Problem

The combined availability calculation presupposes independence:

P(both fail) = P(A fails) × P(B fails) = 0.01 × 0.01 = 0.0001

That only holds if A's failure has no relation to B's. In practice, the copies share almost everything:

the same code one defect takes all of them down
the same configuration one wrong change takes all of them down
the same deployment one bad version takes all of them down
the same dependency it goes down, all of them stop
the same zone power, network, cooling
the same certificate it expires for all of them at the same instant

With a shared dependency, three copies are no better than one for that class of failure.

Core Concepts

Correlation is the variable that matters

The question to ask about any redundancy: what would make every copy fail together?

The list is usually longer than expected, and it is the map of what the redundancy does not protect.

protected by N copies hardware failure, instance failure, process failure
not protected a code defect, wrong configuration,
an expired certificate, a common dependency,
quota exhaustion, human error

The second column contains the most common incidents in modern systems. Redundancy resolves the first and does not touch the second.

The forms of redundancy

active-active every copy serves; losing one reduces capacity
active-passive one serves; the other takes over. See failover
N+1 capacity for N, with one extra copy
N+M tolerates M simultaneous failures

Active-active has a decisive operational advantage: the standby copy is being exercised all the time. In a passive configuration, the standby may have been broken for months with nobody knowing.

That is the practical reason to prefer active-active when possible — not resource utilization, but the fact that the recovery path is the normal path.

N+1 requires absorption capacity

Having one extra copy is not enough if the remaining ones cannot take the load.

3 nodes at 80% utilization
one goes down → the remaining two need 120% → they cannot take it
3 nodes at 60%
one goes down → the remaining two go to 90% → they can

See availability zones and capacity planning.

The headroom is part of the redundancy. Without it, the redundancy exists on the diagram and not in operation.

Diversity reduces correlation, and it costs

Different copies fail for different reasons:

different zones protects against datacenter failure
different regions against a regional disaster
different providers against provider failure
different implementations against a software defect

The last is the most effective against a code defect and the most expensive — maintaining two implementations of the same system rarely justifies itself outside safety-critical contexts.

The first three are practicable, at increasing cost. See multi-region.

Gradual deployment is redundancy in time

Against a code defect, spatial redundancy does not help. What helps is not deploying to everything at the same time:

phased deployment a fraction receives the new version; observe; advance
canary deployment a small amount of traffic on the new version
fast rollback going back in minutes

That protects exactly the class of failure that causes the most incidents in mature systems, and it does not appear in discussions about redundancy — because it is not about having more copies.

Redundancy adds failure modes

Frankness is worth it: more copies mean more things to go wrong.

Split brain. Two copies consider themselves primary. See leader election.

Configuration divergence. The copies stop being identical.

Failover failure. The switching mechanism does not work when triggered. See failover.

Diagnostic complexity. Inconsistent behavior between copies.

Badly implemented redundancy can be less available than a single, well-operated copy.

Mental Model

Redundancy protects against what is independent. The list of what is shared is the list of what it does not resolve.

When to Use

  • Hardware or instance failure is the main threat.
  • Unavailability has a relevant cost.
  • Service needs to be maintained during maintenance.
  • There is an agreed availability requirement.
  • The component is stateless — the redundancy is cheap.

When Not to Use

Without checking the correlation.

With no absorption capacity.

Active-passive without exercising the standby copy.

Against a code defect. There the answer is gradual deployment.

When the cost exceeds that of the unavailability.

With no tested switching mechanism.

Alternatives

  • Fast recovery — instead of avoiding the failure, shortening the time to resume. Frequently cheaper and sufficient.
  • Graceful degradation — operating with less.
  • Gradual deployment — against the most common class of failure.
  • Simplifying — fewer components fail less. It is the least cited alternative and frequently the correct one.

Trade-offs

More redundancyLess
Tolerates more failuresFewer
Higher costLower
More complexityLess
More failure modes of its ownFewer
Idle capacityHigh utilization
Active-activeActive-passive
The standby is exercisedIt may be broken
All capacity in useIdle
No switch to executeA failover to test
Coordination necessarySimpler

Failure Modes

A correlated failure. Every copy goes down together.

Insufficient capacity. The remaining ones saturate.

A broken standby. Never exercised.

Split brain.

Configuration divergence.

A shared certificate or credential expiring.

A shared quota exhausted. Every copy competes for the same external limit.

Common Mistakes

Counting copies instead of assessing independence. Three replicas in the same rack, in the same zone or with the same configuration dependency fail together. What protects is independence, not the number.

Not sizing for the loss. Redundancy with no headroom changes the failure mode: instead of going down right away, the system survives the loss and then saturates with the redistributed load.

Not exercising the standby. A passive component that never receives traffic accumulates silent defects — divergent configuration, an expired certificate, an old version.

Ignoring shared dependencies. DNS, authentication, the control plane and the configuration system are common to every copy, and they take all of them down at the same time.

Not using gradual deployment. The most frequent cause of unavailability is change, and redundancy does not protect against bad code propagated to every replica simultaneously.

Adding redundancy without testing the switching mechanism. The extra copy is only worth it if the switch to it works. With no exercise, you pay for double the infrastructure and keep the same risk.

Real-World Example

A payments platform had redundancy at every layer: three application instances in three zones, a database with a synchronous replica, two gateway providers.

In eighteen months, three incidents took the whole system down. None was a hardware failure.

An expired certificate. The internal certificate used between services expired. Every instance stopped simultaneously, because they shared the same certificate with the same date. Duration: 90 minutes, until somebody identified the cause.

A wrong configuration. A configuration change applied to the three zones at the same time contained an error. All three instances failed to start. The redundancy did not protect, because the change was simultaneous.

A code defect. A version with a memory leak was deployed to every instance. They degraded together, over 40 minutes.

The fixes attacked the correlation, not the quantity:

Staggered certificates. Different expiration dates per zone, with proximity monitoring. An expiring certificate came to degrade one zone, not the system.

Phased configuration. Configuration changes came to be applied zone by zone, with observation between them — the same treatment given to code deployment.

Canary deployment. 5% of the traffic on the new version for 30 minutes, with metrics compared automatically. The next memory leak was detected with 5% impact, not 100%.

An inventory of shared dependencies. An explicit survey of what the three zones have in common. It found four more items: a shared external API quota, a configuration bucket, an internal name resolution service and a single database credential.

And a decision in the opposite direction: the proposal to add a fourth zone was refused. The analysis showed that none of the three incidents would have been avoided by it, and the cost would be significant.

The detail the team highlights: they had redundancy to spare and correlation everywhere. The question "what would make the three zones go down together?" had never been asked — and the answer had seven items.

Practical Exercise

Choose a redundant component in your system and list everything the copies share — code, configuration, certificate, dependency, quota, credential, zone.

Each item on the list is a failure the redundancy does not cover.

Interview Questions

  • Why does the combined availability arithmetic frequently not hold?
  • Why is active-active preferable to active-passive, beyond utilization?
  • Against which class of failure does spatial redundancy not help?